    F or m No . PD S 502A. 24.1 HORIZONT AL INDOOR SINGLE P A CKA GE COOLING UNITS Single P ac kage Coo ling Un its F eaturing: • compac t design • flexibili ty • eas y main tena nce • high qu ality and rel iability • quiet and effic ient scroll co mpressor techn olog y FEA TURES /BENEF ITS All in o ne pac kage — high coo ling efficie ncy , ...

  • Bryant 502A - page 2

    2 T ABLE OF CONTENTS Pa g e F eatures/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Model Nu mber Nome nclature . . . . . . . . . . . . . . . . . . . . . . . . . 2 ARI Capacit y Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Ph ysical Data . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Bryant 502A - page 3

    3 PHYSICAL D A T A LEGEND *Shipping weights include base unit plus packaging. † If components are to be split, additional refrigerant will be needed. **Use T ype L copper only . NO TE: If components are to be split, the maxim um length of refrigerant tubing to be used is 50 equivalent ft, assuming components will be installed in same horizontal p ...

  • Bryant 502A - page 4

    4 FIELD-INST ALLED A CCESSORIES Thermo stat and Subbase — Attract i v e wall-mo unted 24-v access or y provi des pr eci se te mperat ure c ontr ol. Auto matic and Manu al changeo ver mo dels av ailab le. A thermostat s ubbase is av ailab le that works w ith Cycle-L OC ™ circuitr y . If a saf ety device tr ips, comp ress or lo cks out and subbas ...

  • Bryant 502A - page 5

    5 B ASE UNI T DIMENSION S DIMENSIONS (ft-in.) UNIT 502A ABCDE 024 2-5 2-1 5 / 8 1- 5 3 / 4 1-2 1-1 036 2-4 3 / 4 2-2 1- 5 3 / 4 1-2 1-1 048 2-5 2-3 1-11 5 / 8 1-8 7 / 8 1-7 7 / 8 060 2-4 3 / 4 2-2 3 / 4 1-11 5 / 8 1-8 7 / 8 1-7 7 / 8 Unit Compone nt Locations ...

  • Bryant 502A - page 6

    6 SELECTION PROCEDURE (with e xample) I DETERMINE COO LING REQUIREMENTS A T DESIGN CONDITIONS. Given: Gross C ooling Capacity Required (TC) . . . . . . . . . . . . . . . . . . . . . . . . . 39,00 0 Btuh Sensib le Heat Capaci ty (SHC) . . . . . . . . . . . . 30,50 0 Btuh T emperature of Air Entering Condenser . . . . . . . . . . . 95 F T emperature ...

  • Bryant 502A - page 7

    7 PERFORMANCE D A T A (cont) GROSS COOLING CAP A CITIES (cont) LEGEND NO TES: 1. Perf or m ance based on nomin al conden ser airflow l isted in physical da ta table on page 3 . 2. SHC is ba sed on 80 F db te mperature of air e nteri ng the co il. Below 80 F db, subtract (corr factor x cfm) from SHC. Above 80 F db , add (co rr factor x cfm) t o SHC. ...

  • Bryant 502A - page 8

    8 PERFORMANCE D A T A (cont) BEL T DRIVE EV APORA T OR F AN PERFORMANCE (Spec ial Or der Only , Pricing an d or dering on related pri ce pages.) LEGEND NO TE: Pulley setting must be adjusted to limit cfm to 450 cfm/ton maximum. Unit operation bey ond that limit may result in blo w-off and condensate problems . CONDENSER F AN PERFORMANCE LEGEND kW ? ...

  • Bryant 502A - page 9

    9 CONTR OLS OPERA TING SEQUENCE Cooling 1. The r mosta t call s f or co oling . a. Indoor (e v aporator) f an rela y is energiz ed and starts e vap orato r f an. b . Compr essor contact or is energiz ed to star t compre ssor and conde nser fa n (up to a 5-min ute dela y on single- phase u nits). 2. When room the r mostat is satisfi ed, the e v apor ...

  • Bryant 502A - page 10

    10 ELECTRICAL D A T A (cont) ELECTRIC HEA TER ST A TIC PRESSURE DR O P (in. wg) NO TE: Abov e el ectric he aters are not UL or CSA listed f or use with optional hi gh-static ev apora tor-f an motor (048, 060 units only). TYPICAL WIRING SCHEMA TICS ELEC TRIC H EA TER UNIT 88EN UNIT 502A MIN CFM UNIT CFM 600 800 1000 1200 1400 1600 1800 2000 2200 005 ...

  • Bryant 502A - page 11

    11 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator C — Contactor Compressor CAP — Capacitor CB — Circuit Breaker CC — Cooling Com pensator CDT — Compressor Discharge T hermostat COMP — Comp ressor M otor EQUIP — Equip ment FU — Fuse GND — Ground HPS — High-Pressure Switch HR — Heater Relay IFC — ...

  • Bryant 502A - page 12

    12 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator C — Contactor Compressor CAP — Capacitor CB — Circuit Breaker CC — Cooling Com pensator CDT — Compressor Discharge T hermostat CH — Crankcase Hea ter COMP — Comp ressor M otor EQUIP — Equip ment GND — Ground HPS — High-Pressure Switch HR — Heater ...

  • Bryant 502A - page 13

    13 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator BKR W/A T — Breaks wit h Amp T urns C — Contactor Compressor CC — Cooling Com pensator CLO — Comp ressor L ockou t COMP — Comp ressor M otor CT — Current T ransf ormer EQUIP — Equip ment GND — Ground HPS — High-Pressure Switch IFC — Indoor -Fan Cont ...

  • Bryant 502A - page 14

    14 TYPICAL PIPING AND WIRING APPLICA TION D A T A OUTDOOR-AIR TEMPERA T URE OPERA TING LIMIT S (F) Field Splitting Ins tructions — If c omp onen ts ar e s plit , ma xi- mum length of ref rigerant tubing to be us ed is 50 ft, as suming compon ents are ins talled in same hor iz ontal pl ane. Co ndenser ma y be moun ted up to 12-ft a bov e e va pora ...

  • Bryant 502A - page 15

    15 GUIDE S PECIFICA TIONS INDOOR P A CKA GED UNIT HV AC GUIDE SPECIFICA TIONS — SECTION 157 87 SIZE RANGE: 2 T O 5 T ONS, NOMINAL BR Y ANT MODEL NUMBER: 502A PA R T 1 — GENERAL 1.01 SYSTEM DESCRIPTION Indoor mo unted, electrically c ontrolled pac kaged horizon- tal coo ling unit uti lizing a her metic typ e scroll compre ssor . 1.02 QU ALITY AS ...

  • Bryant 502A - page 16

    Copyright 2001 Bryant Heating & Cooling Systems Printed in U.S . A. 1-01 Catalog No. 5250-200 SPECIFICATIONS SUBJE CT TO CHANGE WITHOUT NOTICE UNIT MUST BE INST ALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS GUIDE SPECIFICA TIONS (cont) 3. Co mpressor Cycle De lay: Pre ven ts compress or from restar ting f or a minimum of 5 min utes after s ...

Fabbricante Bryant Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoBryant 502A possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bryant
- manuali per l’uso 502A
- schede prodotto Bryant
- opuscoli
- o etichette energetiche Bryant 502A
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bryant 502A.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bryant 502A, manuali di manutenzione, brevi manuali o manuali utente Bryant 502A. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bryant 502A.

Manuali per l’uso simili

Manuale completo del dispositivo Bryant 502A, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bryant 502A dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bryant 502A.

Il manuale per l’uso completo Bryant, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bryant 502A - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bryant 502A, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bryant 502A che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bryant 502A - che ci dovrebbe aiutare nei primi passi durante l'uso Bryant 502A
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bryant 502A
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bryant 502A in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bryant 502A?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bryant 502A con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bryant 502A è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)