    1.1 Overview SLLU108 – July 2008 XIO3130 EVM The Texas Instruments XIO3130 EVM is a functional implementation of a four-port PCIe-to-PCIe switch. The XIO3130 EVM was designed to allow validation of three separate functional modes. In normal mode, the EVM is configured as a generic PCI Express (PCIe) switch. In hot-plug mode, downstream ports 1 an ...

  • Texas Instruments XIO3130 EVM - page 2

    1.2 Normal-Mode Operation Normal-Mode Operation www.ti.com By default, the EVM should be configured to operate in normal mode. The six jumpers (J7, J11, J13, J14, J15, and J16) should be covering both pins of each header (see Figure 1-2 ). Figure 1-2. Power Jumpers The dipswitch should be configured with SCL slide switch in the up position and DN1_ ...

  • Texas Instruments XIO3130 EVM - page 3

    1.3 Hot-Plug-Mode Operation www.ti.com Hot-Plug-Mode Operation Figure 1-4. GPIO Control Register • General control register (PCI register offset: D4h in each downstream bridge) – RCVR_PRSNT_EN = 0b – PRSNT pin is used to determine whether slot is present – REFCK_DIS = 0b – REFCK enabled – LINK_ACT_RPT_CAP = 1b – Slot is link active re ...

  • Texas Instruments XIO3130 EVM - page 4

    Hot-Plug-Mode Operation www.ti.com Figure 1-6. Dipswitch Configuration The EEPROM (U3) should be reconfigured for hot-plug-mode operation. See Section 1.5 for an explanation of how to configure the EEPROM. Upon deassertion of PERST, the XIO3130 automatically reads data from the EEPROM. This data is used to preset various PCI configuration register ...

  • Texas Instruments XIO3130 EVM - page 5

    1.4 ExpressCard-Mode operation www.ti.com ExpressCard-Mode operation • General control register (PCI register offset: D4h in port 1 and port 2 downstream bridges) – RCVR_PRSNT_EN = 0b – PRSNT pin is used to determine whether slot is present – REFCK_DIS = 0b – REFCK enabled – LINK_ACT_RPT_CAP = 1b – Slot is link active reporting capabl ...

  • Texas Instruments XIO3130 EVM - page 6

    ExpressCard-Mode operation www.ti.com Figure 1-8. ExpressCard Adapter Board To configure the XIO3130 EVM for ExpressCard-mode operation, connect the ribbon cable connector from J1 on the adapter board to one of the matching connectors (J2, J3 or J4) on the XIO3130 EVM board. Then plug the adapter board into the adjacent PCIe slot as shown in Figure ...

  • Texas Instruments XIO3130 EVM - page 7

    www.ti.com ExpressCard-Mode operation Figure 1-9. EVM Configuration for ExpressCard Mode To configure the XIO3130 EVM for ExpressCard-mode operation, the six jumpers (J7, J11, J13, J14, J15, J16) must be populated (see Figure 1-5 ). This routes power directly to slots 1 and 2 bypassing the TPS2363, which is not required for ExpressCard operation. T ...

  • Texas Instruments XIO3130 EVM - page 8

    1.5 Using WinROM to Configure the EEPROM Using WinROM to Configure the EEPROM www.ti.com The EEPROM (U3) will need to be reconfigured for ExpressCard-mode operation. See Section 1.5 for an explanation of how to configure the EEPROM. Upon deassertion of PERST the XIO3130 will automatically read data from the EEPROM. This data is used to pre-set vari ...

  • Texas Instruments XIO3130 EVM - page 9

    www.ti.com Using WinROM to Configure the EEPROM Figure 1-11. EEPROM Data To update the entire EEPROM from a .dat file that was provided by TI, right click on the XIO3130 entry (see Figure 1-12 ). Select the option "Program EEPROM Data From File." Figure 1-12. Updating the EEPROM SLLU108 – July 2008 XIO3130 EVM 9 Submit Documentation Fee ...

  • Texas Instruments XIO3130 EVM - page 10

    Using WinROM to Configure the EEPROM www.ti.com A new dialog box appears that allows the user to select which .dat file to use to program the EEPROM (see Figure 1-13 ). Select from one of the three operating modes supplied with the EVM. Figure 1-13. Selecting a .dat File After the Open button has been pressed, a new dialog box opens asking if the u ...

  • Texas Instruments XIO3130 EVM - page 11

    1.6 Using the TopHAT Utility www.ti.com Using the TopHAT Utility Once flashing has completed, the contents of the EEPROM now contains the data from the .dat file. However, this data is not yet present in the PCI configuration space of the XIO3130. Once flashing has finished, WinROM displays a dialog box reminding the user to power cycle the system. ...

  • Texas Instruments XIO3130 EVM - page 12

    Using the TopHAT Utility www.ti.com Figure 1-15. TopHAT 12 XIO3130 EVM SLLU108 – July 2008 Submit Documentation Feedback ...

  • Texas Instruments XIO3130 EVM - page 13

    www.ti.com Using the TopHAT Utility TopHAT parses the PCI configuration space looking for any capability structure. If it finds a capability structure, a new icon and description of the capability will show under the device. For example, under the XIO3130 PCI/PCI bridge (TI) entry, a capability for Power Management Capability Structure is shown wit ...

  • Texas Instruments XIO3130 EVM - page 14

    Trademarks Using the TopHAT Utility www.ti.com Figure 1-17. PCI Registers Any bit in the PCI configuration space can be modified using the PCI Registers dialog box. A new value can be directly typed into the “New Value” edit box or entered by pressing any of the bit numbers below the edit box. The new register value will not be written until th ...

  • Texas Instruments XIO3130 EVM - page 15

    EVALUATION BOARD/KIT IMPORTANT NOTICE Texas Instruments (TI) provides the enclosed product(s) under the following conditions: This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling th ...

  • Texas Instruments XIO3130 EVM - page 16

    EVM WARNINGS AND RESTRICTIONS It is important to operate this EVM within the input voltage range of 0 V to 3.6 V or –-0.6 V to 0.6 V and the output voltage range of 0 V to 3.6 V or –-0.6 V to 0.6 V. Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are questions concerning the inp ...

  • Texas Instruments XIO3130 EVM - page 17

    IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders ...

Fabricant Texas Instruments Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilTexas Instruments XIO3130 EVM peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Texas Instruments
- manuels d’utilisations XIO3130 EVM
- fiches produit Texas Instruments
- dépliants
- ou étiquettes-énergie Texas Instruments XIO3130 EVM
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Texas Instruments XIO3130 EVM.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Texas Instruments XIO3130 EVM, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Texas Instruments XIO3130 EVM. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Texas Instruments XIO3130 EVM.

Manuel d’utilisation complet de l’appareil Texas Instruments XIO3130 EVM, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Texas Instruments XIO3130 EVM par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Texas Instruments XIO3130 EVM.

Le manuel d’utilisation complet Texas Instruments, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Texas Instruments XIO3130 EVM - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Texas Instruments XIO3130 EVM, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lTexas Instruments XIO3130 EVM qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Texas Instruments XIO3130 EVM - qui devraient nous aider dans les premières étapes lors de l'utilisation Texas Instruments XIO3130 EVM
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Texas Instruments XIO3130 EVM
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Texas Instruments XIO3130 EVM dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Texas Instruments XIO3130 EVM?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Texas Instruments XIO3130 EVM, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Texas Instruments XIO3130 EVM il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)