    1.1 Overview SLLU108 – July 2008 XIO3130 EVM The Texas Instruments XIO3130 EVM is a functional implementation of a four-port PCIe-to-PCIe switch. The XIO3130 EVM was designed to allow validation of three separate functional modes. In normal mode, the EVM is configured as a generic PCI Express (PCIe) switch. In hot-plug mode, downstream ports 1 an ...

  • Texas Instruments XIO3130 EVM - page 2

    1.2 Normal-Mode Operation Normal-Mode Operation www.ti.com By default, the EVM should be configured to operate in normal mode. The six jumpers (J7, J11, J13, J14, J15, and J16) should be covering both pins of each header (see Figure 1-2 ). Figure 1-2. Power Jumpers The dipswitch should be configured with SCL slide switch in the up position and DN1_ ...

  • Texas Instruments XIO3130 EVM - page 3

    1.3 Hot-Plug-Mode Operation www.ti.com Hot-Plug-Mode Operation Figure 1-4. GPIO Control Register • General control register (PCI register offset: D4h in each downstream bridge) – RCVR_PRSNT_EN = 0b – PRSNT pin is used to determine whether slot is present – REFCK_DIS = 0b – REFCK enabled – LINK_ACT_RPT_CAP = 1b – Slot is link active re ...

  • Texas Instruments XIO3130 EVM - page 4

    Hot-Plug-Mode Operation www.ti.com Figure 1-6. Dipswitch Configuration The EEPROM (U3) should be reconfigured for hot-plug-mode operation. See Section 1.5 for an explanation of how to configure the EEPROM. Upon deassertion of PERST, the XIO3130 automatically reads data from the EEPROM. This data is used to preset various PCI configuration register ...

  • Texas Instruments XIO3130 EVM - page 5

    1.4 ExpressCard-Mode operation www.ti.com ExpressCard-Mode operation • General control register (PCI register offset: D4h in port 1 and port 2 downstream bridges) – RCVR_PRSNT_EN = 0b – PRSNT pin is used to determine whether slot is present – REFCK_DIS = 0b – REFCK enabled – LINK_ACT_RPT_CAP = 1b – Slot is link active reporting capabl ...

  • Texas Instruments XIO3130 EVM - page 6

    ExpressCard-Mode operation www.ti.com Figure 1-8. ExpressCard Adapter Board To configure the XIO3130 EVM for ExpressCard-mode operation, connect the ribbon cable connector from J1 on the adapter board to one of the matching connectors (J2, J3 or J4) on the XIO3130 EVM board. Then plug the adapter board into the adjacent PCIe slot as shown in Figure ...

  • Texas Instruments XIO3130 EVM - page 7

    www.ti.com ExpressCard-Mode operation Figure 1-9. EVM Configuration for ExpressCard Mode To configure the XIO3130 EVM for ExpressCard-mode operation, the six jumpers (J7, J11, J13, J14, J15, J16) must be populated (see Figure 1-5 ). This routes power directly to slots 1 and 2 bypassing the TPS2363, which is not required for ExpressCard operation. T ...

  • Texas Instruments XIO3130 EVM - page 8

    1.5 Using WinROM to Configure the EEPROM Using WinROM to Configure the EEPROM www.ti.com The EEPROM (U3) will need to be reconfigured for ExpressCard-mode operation. See Section 1.5 for an explanation of how to configure the EEPROM. Upon deassertion of PERST the XIO3130 will automatically read data from the EEPROM. This data is used to pre-set vari ...

  • Texas Instruments XIO3130 EVM - page 9

    www.ti.com Using WinROM to Configure the EEPROM Figure 1-11. EEPROM Data To update the entire EEPROM from a .dat file that was provided by TI, right click on the XIO3130 entry (see Figure 1-12 ). Select the option "Program EEPROM Data From File." Figure 1-12. Updating the EEPROM SLLU108 – July 2008 XIO3130 EVM 9 Submit Documentation Fee ...

  • Texas Instruments XIO3130 EVM - page 10

    Using WinROM to Configure the EEPROM www.ti.com A new dialog box appears that allows the user to select which .dat file to use to program the EEPROM (see Figure 1-13 ). Select from one of the three operating modes supplied with the EVM. Figure 1-13. Selecting a .dat File After the Open button has been pressed, a new dialog box opens asking if the u ...

  • Texas Instruments XIO3130 EVM - page 11

    1.6 Using the TopHAT Utility www.ti.com Using the TopHAT Utility Once flashing has completed, the contents of the EEPROM now contains the data from the .dat file. However, this data is not yet present in the PCI configuration space of the XIO3130. Once flashing has finished, WinROM displays a dialog box reminding the user to power cycle the system. ...

  • Texas Instruments XIO3130 EVM - page 12

    Using the TopHAT Utility www.ti.com Figure 1-15. TopHAT 12 XIO3130 EVM SLLU108 – July 2008 Submit Documentation Feedback ...

  • Texas Instruments XIO3130 EVM - page 13

    www.ti.com Using the TopHAT Utility TopHAT parses the PCI configuration space looking for any capability structure. If it finds a capability structure, a new icon and description of the capability will show under the device. For example, under the XIO3130 PCI/PCI bridge (TI) entry, a capability for Power Management Capability Structure is shown wit ...

  • Texas Instruments XIO3130 EVM - page 14

    Trademarks Using the TopHAT Utility www.ti.com Figure 1-17. PCI Registers Any bit in the PCI configuration space can be modified using the PCI Registers dialog box. A new value can be directly typed into the “New Value” edit box or entered by pressing any of the bit numbers below the edit box. The new register value will not be written until th ...

  • Texas Instruments XIO3130 EVM - page 15

    EVALUATION BOARD/KIT IMPORTANT NOTICE Texas Instruments (TI) provides the enclosed product(s) under the following conditions: This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling th ...

  • Texas Instruments XIO3130 EVM - page 16

    EVM WARNINGS AND RESTRICTIONS It is important to operate this EVM within the input voltage range of 0 V to 3.6 V or –-0.6 V to 0.6 V and the output voltage range of 0 V to 3.6 V or –-0.6 V to 0.6 V. Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are questions concerning the inp ...

  • Texas Instruments XIO3130 EVM - page 17

    IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders ...

メーカー Texas Instruments カテゴリー Switch

Texas Instruments XIO3130 EVMのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- XIO3130 EVMの取扱説明書
- Texas Instrumentsの製品カード
- パンフレット
- またはTexas Instruments XIO3130 EVMの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Texas Instruments XIO3130 EVMの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Texas Instruments XIO3130 EVMの取り付け説明書、サービスマニュアル、簡易説明書、またはTexas Instruments XIO3130 EVMのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Texas Instruments XIO3130 EVMの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Texas Instruments XIO3130 EVMデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがTexas Instruments XIO3130 EVMを使用するのを助ける技術的文書のことです。説明書は通常、全てのTexas Instruments XIO3130 EVMユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Texas Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Texas Instruments XIO3130 EVMの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははTexas Instruments XIO3130 EVMの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Texas Instruments XIO3130 EVMに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Texas Instruments XIO3130 EVMデバイスの基本機能を使うにあたってのヒント。 Texas Instruments XIO3130 EVMのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Texas Instruments XIO3130 EVMに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるTexas Instruments XIO3130 EVMのメーカー/サービスへの連絡先に関する情報。

Texas Instruments XIO3130 EVMについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもTexas Instruments XIO3130 EVMの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがTexas Instruments XIO3130 EVMで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)