    1.1 Overview SLLU108 – July 2008 XIO3130 EVM The Texas Instruments XIO3130 EVM is a functional implementation of a four-port PCIe-to-PCIe switch. The XIO3130 EVM was designed to allow validation of three separate functional modes. In normal mode, the EVM is configured as a generic PCI Express (PCIe) switch. In hot-plug mode, downstream ports 1 an ...

  • Texas Instruments XIO3130 EVM - page 2

    1.2 Normal-Mode Operation Normal-Mode Operation www.ti.com By default, the EVM should be configured to operate in normal mode. The six jumpers (J7, J11, J13, J14, J15, and J16) should be covering both pins of each header (see Figure 1-2 ). Figure 1-2. Power Jumpers The dipswitch should be configured with SCL slide switch in the up position and DN1_ ...

  • Texas Instruments XIO3130 EVM - page 3

    1.3 Hot-Plug-Mode Operation www.ti.com Hot-Plug-Mode Operation Figure 1-4. GPIO Control Register • General control register (PCI register offset: D4h in each downstream bridge) – RCVR_PRSNT_EN = 0b – PRSNT pin is used to determine whether slot is present – REFCK_DIS = 0b – REFCK enabled – LINK_ACT_RPT_CAP = 1b – Slot is link active re ...

  • Texas Instruments XIO3130 EVM - page 4

    Hot-Plug-Mode Operation www.ti.com Figure 1-6. Dipswitch Configuration The EEPROM (U3) should be reconfigured for hot-plug-mode operation. See Section 1.5 for an explanation of how to configure the EEPROM. Upon deassertion of PERST, the XIO3130 automatically reads data from the EEPROM. This data is used to preset various PCI configuration register ...

  • Texas Instruments XIO3130 EVM - page 5

    1.4 ExpressCard-Mode operation www.ti.com ExpressCard-Mode operation • General control register (PCI register offset: D4h in port 1 and port 2 downstream bridges) – RCVR_PRSNT_EN = 0b – PRSNT pin is used to determine whether slot is present – REFCK_DIS = 0b – REFCK enabled – LINK_ACT_RPT_CAP = 1b – Slot is link active reporting capabl ...

  • Texas Instruments XIO3130 EVM - page 6

    ExpressCard-Mode operation www.ti.com Figure 1-8. ExpressCard Adapter Board To configure the XIO3130 EVM for ExpressCard-mode operation, connect the ribbon cable connector from J1 on the adapter board to one of the matching connectors (J2, J3 or J4) on the XIO3130 EVM board. Then plug the adapter board into the adjacent PCIe slot as shown in Figure ...

  • Texas Instruments XIO3130 EVM - page 7

    www.ti.com ExpressCard-Mode operation Figure 1-9. EVM Configuration for ExpressCard Mode To configure the XIO3130 EVM for ExpressCard-mode operation, the six jumpers (J7, J11, J13, J14, J15, J16) must be populated (see Figure 1-5 ). This routes power directly to slots 1 and 2 bypassing the TPS2363, which is not required for ExpressCard operation. T ...

  • Texas Instruments XIO3130 EVM - page 8

    1.5 Using WinROM to Configure the EEPROM Using WinROM to Configure the EEPROM www.ti.com The EEPROM (U3) will need to be reconfigured for ExpressCard-mode operation. See Section 1.5 for an explanation of how to configure the EEPROM. Upon deassertion of PERST the XIO3130 will automatically read data from the EEPROM. This data is used to pre-set vari ...

  • Texas Instruments XIO3130 EVM - page 9

    www.ti.com Using WinROM to Configure the EEPROM Figure 1-11. EEPROM Data To update the entire EEPROM from a .dat file that was provided by TI, right click on the XIO3130 entry (see Figure 1-12 ). Select the option "Program EEPROM Data From File." Figure 1-12. Updating the EEPROM SLLU108 – July 2008 XIO3130 EVM 9 Submit Documentation Fee ...

  • Texas Instruments XIO3130 EVM - page 10

    Using WinROM to Configure the EEPROM www.ti.com A new dialog box appears that allows the user to select which .dat file to use to program the EEPROM (see Figure 1-13 ). Select from one of the three operating modes supplied with the EVM. Figure 1-13. Selecting a .dat File After the Open button has been pressed, a new dialog box opens asking if the u ...

  • Texas Instruments XIO3130 EVM - page 11

    1.6 Using the TopHAT Utility www.ti.com Using the TopHAT Utility Once flashing has completed, the contents of the EEPROM now contains the data from the .dat file. However, this data is not yet present in the PCI configuration space of the XIO3130. Once flashing has finished, WinROM displays a dialog box reminding the user to power cycle the system. ...

  • Texas Instruments XIO3130 EVM - page 12

    Using the TopHAT Utility www.ti.com Figure 1-15. TopHAT 12 XIO3130 EVM SLLU108 – July 2008 Submit Documentation Feedback ...

  • Texas Instruments XIO3130 EVM - page 13

    www.ti.com Using the TopHAT Utility TopHAT parses the PCI configuration space looking for any capability structure. If it finds a capability structure, a new icon and description of the capability will show under the device. For example, under the XIO3130 PCI/PCI bridge (TI) entry, a capability for Power Management Capability Structure is shown wit ...

  • Texas Instruments XIO3130 EVM - page 14

    Trademarks Using the TopHAT Utility www.ti.com Figure 1-17. PCI Registers Any bit in the PCI configuration space can be modified using the PCI Registers dialog box. A new value can be directly typed into the “New Value” edit box or entered by pressing any of the bit numbers below the edit box. The new register value will not be written until th ...

  • Texas Instruments XIO3130 EVM - page 15

    EVALUATION BOARD/KIT IMPORTANT NOTICE Texas Instruments (TI) provides the enclosed product(s) under the following conditions: This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling th ...

  • Texas Instruments XIO3130 EVM - page 16

    EVM WARNINGS AND RESTRICTIONS It is important to operate this EVM within the input voltage range of 0 V to 3.6 V or –-0.6 V to 0.6 V and the output voltage range of 0 V to 3.6 V or –-0.6 V to 0.6 V. Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are questions concerning the inp ...

  • Texas Instruments XIO3130 EVM - page 17

    IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders ...

Fabbricante Texas Instruments Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoTexas Instruments XIO3130 EVM possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Texas Instruments
- manuali per l’uso XIO3130 EVM
- schede prodotto Texas Instruments
- opuscoli
- o etichette energetiche Texas Instruments XIO3130 EVM
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Texas Instruments XIO3130 EVM.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Texas Instruments XIO3130 EVM, manuali di manutenzione, brevi manuali o manuali utente Texas Instruments XIO3130 EVM. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Texas Instruments XIO3130 EVM.

Manuale completo del dispositivo Texas Instruments XIO3130 EVM, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Texas Instruments XIO3130 EVM dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Texas Instruments XIO3130 EVM.

Il manuale per l’uso completo Texas Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Texas Instruments XIO3130 EVM - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Texas Instruments XIO3130 EVM, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Texas Instruments XIO3130 EVM che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Texas Instruments XIO3130 EVM - che ci dovrebbe aiutare nei primi passi durante l'uso Texas Instruments XIO3130 EVM
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Texas Instruments XIO3130 EVM
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Texas Instruments XIO3130 EVM in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Texas Instruments XIO3130 EVM?

Utilizza il modulo sottostante

Se non hai risolto il problema con Texas Instruments XIO3130 EVM con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Texas Instruments XIO3130 EVM è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)