Manuel d’utilisation APC SYPM2KU

22 pages 0.99 mb
Télécharger

Aller à la page of 22

Summary
  • APC SYPM2KU - page 1

    990-1031, Revisi on 1 8/00 APC Symmetra RM Inst allation Manual English ...

  • APC SYPM2KU - page 2

    990-1031, Revisi on 1 8/00 Limited W arr ant y American Pow er Convers ion (APC) wa rrants its produ cts to be free f rom defects in ma terials and w orkmanship for a period of two y ears from the date of purchase, except in In dia where the period i s one year f or battery module(s). Its obligation under this warrant y is limited to rep airing or ...

  • APC SYPM2KU - page 3

    990-1031, Revisi on 1 8/00 Table of Conte nts Chapter 1: Safet y Information ............................................................. 1 Conventions Used in this Manual ......................................................... 1 Handling Safe ty ..................................................................................... 1 Electrica l ...

  • APC SYPM2KU - page 4

    990-1031, Revisi on 1 8/00 List of Fig ures Figure 1: Sym metra RM ......................................................................................................... ............................ 5 Figure 2: Fron t View of the Sy mmetra RM ....................................................................................... ................ ...

  • APC SYPM2KU - page 5

    1 C HA PT ER 1: S AF E T Y I NFO RMA TION This Safety sectio n contai ns impo rtant instructions that should be follo wed during installation a nd main te nance of the APC equipment and batteries. It is intended for APC customers who setup, install, relocate, o r m aintai n APC equi p m e nt . Connection to the branch circuit (mains) must be perfor ...

  • APC SYPM2KU - page 6

    2 • Use one h and, whenever possible, to conn ect or disconnect sign al cables to avoid a possi ble shock from touching tw o surfaces with different electrical groun ds. • Connect th e eq uip m ent to a three wire AC outlet (two poles plus ground). The receptacle must be conn ected to appropriate bran ch circuit/mains protection (f use or circu ...

  • APC SYPM2KU - page 7

    3 Rec ycling of Batteries See your dealer or Re placing Modules in the S Y MMETRA RM O PER ATION M A NUAL , for information on replacement battery kits an d battery recycling. • Do not insta ll the batt ery module( s) in the frame until you ar e ready to po wer up the Symmetra RM. Failure to so can resu lt in a deep di scharge of the bat teries, ...

  • APC SYPM2KU - page 8

    4 ...

  • APC SYPM2KU - page 9

    5 C HA PT ER 2: B AS I CS About Y our UPS The Symmetra RM is a h igh-performance, uninterruptible pow er system in a “power array ” configuration, designed to power high availability server s and o ther se nsitive electronic equipment. It provides conditioned, reliable AC power to con nected equipment, and prov ides protection from pow er black ...

  • APC SYPM2KU - page 10

    6 How T o Contact APC Internet http://www.apc.com / support North America Phone 1.800 .800.4272 Fax 1.401.788.27 43 Email apctech@apcc.com Latin America, South America Argen tina .....0800.9.APCC (0800.9 .2722) Mexico....................... 95.800.804.4283 Brazil ........... 0800.12. 72.21 Uruguay ..................... 000.413. 598.2139 Colombia .. ...

  • APC SYPM2KU - page 11

    7 Product Overview Front View Component Identification Figure 2: Front View of the Symmetra RM Power Module(s)  : The Sy mmetra RM can support betw een one and four pow er module s. Each module provides 2 k VA/1.4 KW pow er. Redundant Intelligence M odule  : The redundant intelligence module (RIM) is a backup version o f the main intell igenc ...

  • APC SYPM2KU - page 12

    8 Rear View Component Identification Figure 3: Rear Vi ew of the Symm etra RM (200/208 Vac / L1-L2-G version shown) Syste m Fan  : T he sy stem fan can be replaced in the f ield. Refer to Replacing t he System Fan, in the S YMMET RA RM O PERATION M A NUAL , for instructions. Accessory Ports  : A PC m anufac tures a se t of auxiliary user inte ...

  • APC SYPM2KU - page 13

    9 Input Voltag e Selection Switch  : Set this switch to th e appropriate sett ing, ei ther 200/208 (L1- L2-G ) or 220/230/24 0 (L1-N- G) before pow ering up the Symm etra RM. Products r ated 200/208 a re typi cally installed in N orth America (208 V, phas e to phase, grou nding conductor) and Japan (200V, phase to ph ase, groun ding conductor). ...

  • APC SYPM2KU - page 14

    10 System Blo ck Diagram Figure 4: System Block Diagram MIM RIM COM Card Accessor y Cards Powe rV iew D is pla y DB9 COM Port Battery Monitor Bus External Battery Power Input Circuit Breaker A CCESSO RY PA SS THROUG H BUS Backfeed Relay Automatic By pass Manual By pa ss External Battery Frame COM Power or Battery Module Power or Battery Module Powe ...

  • APC SYPM2KU - page 15

    11 C HA PT ER 3: I NST AL L A T ION Unp acking APC has taken care to design robus t packaging for you r product. However, accident s and damage m ay occur during shipmen t. Inspection Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save i t for reuse or dispos e of it properly . Contents ...

  • APC SYPM2KU - page 16

    12 Determ ine the Locatio n of the S ymm etra RM in the Rac k 1. Select a location for th e S ym metra RM in your NetShelter enclosure or other 19-in ch (46.5 cm) rack. Select a location with adequate air flo w that is fr ee from excess ive dust. Ensure that the air vents o n the sid es of the Sym metra are not b locked. • The Symmet ra RM is hea ...

  • APC SYPM2KU - page 17

    13 Install th e UPS int o the Rack 1. With tw o people supporting t he Symmetra R M, one on each side, carefully align the cleats on the sides of the unit with the grooves on th e mounting rails. Slide the unit into the rack completely. 2. Use the six (6) o rna me nt al scre ws, supp lied with the unit, to attach the mounting brackets to the rack p ...

  • APC SYPM2KU - page 18

    14 1. Make sure the main circuit break er  , located on the rear panel, is in the OFF positio n. 2. Select the appropriate w ire size and connectors, accordin g to local codes. For m ost applicat ions, #10 AWG (5 s q. mm) wire shoul d be suffi cient. 3. Remove th e input wiring access door by unscrewing the single screw that holds th e access pa ...

  • APC SYPM2KU - page 19

    15 Use one of the f ollowing cable types to conn ect the Symmetra RM to the EPO switch: CL2 Class 2 cable for general use. CL2P Plenum cable for use in ducts, plen ums, and other s paces used for environm ental air. CL2R Riser cable for use in a vertical run in a shaft of from fl oor to floor. CL2X Limited use cable f or use in dwellings and for u ...

  • APC SYPM2KU - page 20

    16 Install b attery modules just prior to running the Sym metra RM. Th e battery modu les discharge slo wly when loaded p rematurel y and can be damaged p ermanently. Each battery module weig hs 21.8 kg (48 lbs). Two peop le are req uired to i nstall or rem ove battery m odules. Battery Module: W ith one person on either side of the battery module, ...

  • APC SYPM2KU - page 21

    17 A PPEND IX A : E LECTRICAL W IRING C HECKLIST Complete this checklist to ensu re that the Symmetra RM has been wired properly . Ensure that all switches (system enable, maintenance bypass, input circuit breaker, and bypass circuit breaker) are in the Off or Stand By position. Turn o ff or unplug all equipment connected to the Symm et ra RM. Ensu ...

  • APC SYPM2KU - page 22

    18 5. Record input v oltages below and compare the values with the m eas ured v oltages from step 1. If the tw o measurem ents are signif icantly differen t, contact APC Sy mmetra technical support. Vin 1: ________________________________________________________ 6. Switch the maintenance b ypass switch on. Disregar d any LED ind icator or fault m e ...

Fabricant APC Catégorie Power Supply

Les documents que nous recevons du fabricant de l'appareilAPC SYPM2KU peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques APC
- manuels d’utilisations SYPM2KU
- fiches produit APC
- dépliants
- ou étiquettes-énergie APC SYPM2KU
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation APC SYPM2KU.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation APC SYPM2KU, manuels d’entretien, brefs manuels ou manuels de l’utilisateur APC SYPM2KU. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit APC SYPM2KU.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil APC SYPM2KU, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser APC SYPM2KU par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs APC SYPM2KU.

Le manuel d’utilisation complet APC, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel APC SYPM2KU - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières APC SYPM2KU, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAPC SYPM2KU qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil APC SYPM2KU - qui devraient nous aider dans les premières étapes lors de l'utilisation APC SYPM2KU
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de APC SYPM2KU
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service APC SYPM2KU dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de APC SYPM2KU?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec APC SYPM2KU, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec APC SYPM2KU il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)