Manuel d’utilisation Actron 9040

12 pages 0.64 mb
Télécharger

Aller à la page of 12

Summary
  • Actron 9040 - page 1

    Retrieves Global (Generic) OBD II diagnostic codes and displays their definitions on Foreign and Domestic OBD II compliant vehicles 9040 Global OBD II Code Scanner ® Content s Safety Precautions ................................................................................... 2 About OBD II ....................................................... ...

  • Actron 9040 - page 2

    2 OBD II stands for On-Board Diagnostics version II. OBD II is a system that the Society of Automotive Engineers (SAE) developed to standardize automotive electronic diagnosis to minimize vehicle pollution and to allow you to use the same tool to test any make and model without special adapters. The SAE established guidelines that provide:  a un ...

  • Actron 9040 - page 3

    3 Diagnostic T r ouble Code(s) (DTC) Diagnostic Trouble Codes (DTCs) consist of a five-digit alphanumeric code in the for- mat shown below . When the On-Board Computer recognizes and identifies a problem in the computer-monitored systems, a DTC for that fault is stored in memory . These codes are intended to help you determine the root cause of a p ...

  • Actron 9040 - page 4

    4 Control and Indicators The scan tool is designed to be as intuitive as possible. All menu and lists operate the same way .  ENTER Key - selects displayed items and moves cursor in the Code Lookup function.  YES/UP Arrow Key - responds yes to prompts, scrolls up and changes numbers in Code Lookup.  NO/DOWN Arrow Key - responds no to promp ...

  • Actron 9040 - page 5

    5 Using the Code Scanner ® Turn the ignition key to the KOEO or KOER. Select Read Codes and press ENTER . If there are no codes stored in vehicle memory , a System Pass message displays. If codes have been stored in vehicle memory , then the num- ber of codes and type display (i.e. = 1 of 3 ; ). Press the DOWN arrow to view the codes. The de ...

  • Actron 9040 - page 6

    6 Using the Code Scanner ® Select I/M Monitors and press the ENTER key . Each I/M monitor and its status display per screen. Use the arrow keys to view them. When done, press the BACK key .  A status of Ready means that the required driving conditions for that monitor have been meet and it passed.  A status of Not Ready means tha ...

  • Actron 9040 - page 7

    7  Inspect all vacuum hoses for: * Correct routing. Refer to vehicle service manual, or V ehicle Emission Control Information (VECI) decal located in the engine compartment. * Pinches and kinks. * S plits, cut s or breaks  Inspect wiring for: * Contact with sharp edges (a common problem). * Contact with hot surfaces, such as exhaust  Inspe ...

  • Actron 9040 - page 8

    8 V ehicle Service Information V ehicle service manuals containing additional diagnostic information are available at most auto parts stores or the local library . If unable to locate them at those locations, write the below listed publishers for availability and pricing. Please be sure to specify the make, model and year of vehicle. Chilton Book C ...

  • Actron 9040 - page 9

    9 Gl obal P arameter li st All parameter identification data (PID) listed was verified on actual vehicles to guaran- tee accuracy . Definitions used to describe all PIDs were obtained from reliable sources and are accurate at time of printing. It is possible that some newer vehicles may contain data different from that listed in Appendix A. Always ...

  • Actron 9040 - page 10

    10 CALC LOAD (0 - 100%) Calulated LOAD Value indicates load on engine. C A T TEMPxy (-40°C - 6513.5°C) or (-40 - 9999.9F) Cataly st T emperature Bank shall display catalyst substrate temperature for bank catalyst, if used by control module strategy for on board diagnostics monitoring, bank, sensor catalyst or tempera- ture sensor. CLR DST (0km-65 ...

  • Actron 9040 - page 11

    11 4. OPEN2: The PCM is operating in Open Loop control strategy due to detected system fault. Certain actuator or sensor faults will cause module to use an open loop strategy . 5. CLSD1: Closed Loop control is current storage being used by module, but a fault with at least one O2 sensor has been detected. The control system may be using single O2 f ...

  • Actron 9040 - page 12

    ©2004 SPX Actron. All Rights Reserved. Printed in USA 0002-002-2356 REL TPS (0 - 100%) Relative Throttle Position is relative throttle position at normal position. SECOND AI R (AI R_ST AT : UPS, DNS or OFF) Commanded Secondary Air St atus is on newer vehicles and actuators to control pollution control. UPS - UP STREAM module is demanding that seco ...

Fabricant Actron Catégorie Scanner

Les documents que nous recevons du fabricant de l'appareilActron 9040 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Actron
- manuels d’utilisations 9040
- fiches produit Actron
- dépliants
- ou étiquettes-énergie Actron 9040
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Actron 9040.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Actron 9040, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Actron 9040. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Actron 9040.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Actron 9040, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Actron 9040 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Actron 9040.

Le manuel d’utilisation complet Actron, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Actron 9040 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Actron 9040, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lActron 9040 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Actron 9040 - qui devraient nous aider dans les premières étapes lors de l'utilisation Actron 9040
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Actron 9040
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Actron 9040 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Actron 9040?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Actron 9040, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Actron 9040 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)