    Retrieves Global (Generic) OBD II diagnostic codes and displays their definitions on Foreign and Domestic OBD II compliant vehicles 9040 Global OBD II Code Scanner ® Content s Safety Precautions ................................................................................... 2 About OBD II ....................................................... ...

  • Actron 9040 - page 2

    2 OBD II stands for On-Board Diagnostics version II. OBD II is a system that the Society of Automotive Engineers (SAE) developed to standardize automotive electronic diagnosis to minimize vehicle pollution and to allow you to use the same tool to test any make and model without special adapters. The SAE established guidelines that provide:  a un ...

  • Actron 9040 - page 3

    3 Diagnostic T r ouble Code(s) (DTC) Diagnostic Trouble Codes (DTCs) consist of a five-digit alphanumeric code in the for- mat shown below . When the On-Board Computer recognizes and identifies a problem in the computer-monitored systems, a DTC for that fault is stored in memory . These codes are intended to help you determine the root cause of a p ...

  • Actron 9040 - page 4

    4 Control and Indicators The scan tool is designed to be as intuitive as possible. All menu and lists operate the same way .  ENTER Key - selects displayed items and moves cursor in the Code Lookup function.  YES/UP Arrow Key - responds yes to prompts, scrolls up and changes numbers in Code Lookup.  NO/DOWN Arrow Key - responds no to promp ...

  • Actron 9040 - page 5

    5 Using the Code Scanner ® Turn the ignition key to the KOEO or KOER. Select Read Codes and press ENTER . If there are no codes stored in vehicle memory , a System Pass message displays. If codes have been stored in vehicle memory , then the num- ber of codes and type display (i.e. = 1 of 3 ; ). Press the DOWN arrow to view the codes. The de ...

  • Actron 9040 - page 6

    6 Using the Code Scanner ® Select I/M Monitors and press the ENTER key . Each I/M monitor and its status display per screen. Use the arrow keys to view them. When done, press the BACK key .  A status of Ready means that the required driving conditions for that monitor have been meet and it passed.  A status of Not Ready means tha ...

  • Actron 9040 - page 7

    7  Inspect all vacuum hoses for: * Correct routing. Refer to vehicle service manual, or V ehicle Emission Control Information (VECI) decal located in the engine compartment. * Pinches and kinks. * S plits, cut s or breaks  Inspect wiring for: * Contact with sharp edges (a common problem). * Contact with hot surfaces, such as exhaust  Inspe ...

  • Actron 9040 - page 8

    8 V ehicle Service Information V ehicle service manuals containing additional diagnostic information are available at most auto parts stores or the local library . If unable to locate them at those locations, write the below listed publishers for availability and pricing. Please be sure to specify the make, model and year of vehicle. Chilton Book C ...

  • Actron 9040 - page 9

    9 Gl obal P arameter li st All parameter identification data (PID) listed was verified on actual vehicles to guaran- tee accuracy . Definitions used to describe all PIDs were obtained from reliable sources and are accurate at time of printing. It is possible that some newer vehicles may contain data different from that listed in Appendix A. Always ...

  • Actron 9040 - page 10

    10 CALC LOAD (0 - 100%) Calulated LOAD Value indicates load on engine. C A T TEMPxy (-40°C - 6513.5°C) or (-40 - 9999.9F) Cataly st T emperature Bank shall display catalyst substrate temperature for bank catalyst, if used by control module strategy for on board diagnostics monitoring, bank, sensor catalyst or tempera- ture sensor. CLR DST (0km-65 ...

  • Actron 9040 - page 11

    11 4. OPEN2: The PCM is operating in Open Loop control strategy due to detected system fault. Certain actuator or sensor faults will cause module to use an open loop strategy . 5. CLSD1: Closed Loop control is current storage being used by module, but a fault with at least one O2 sensor has been detected. The control system may be using single O2 f ...

  • Actron 9040 - page 12

    ©2004 SPX Actron. All Rights Reserved. Printed in USA 0002-002-2356 REL TPS (0 - 100%) Relative Throttle Position is relative throttle position at normal position. SECOND AI R (AI R_ST AT : UPS, DNS or OFF) Commanded Secondary Air St atus is on newer vehicles and actuators to control pollution control. UPS - UP STREAM module is demanding that seco ...

Fabbricante Actron Categoria Scanner

I documenti che otteniamo dal fabbricante del dispositivoActron 9040 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Actron
- manuali per l’uso 9040
- schede prodotto Actron
- opuscoli
- o etichette energetiche Actron 9040
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Actron 9040.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Actron 9040, manuali di manutenzione, brevi manuali o manuali utente Actron 9040. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Actron 9040.

Manuali per l’uso simili

Manuale completo del dispositivo Actron 9040, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Actron 9040 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Actron 9040.

Il manuale per l’uso completo Actron, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Actron 9040 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Actron 9040, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Actron 9040 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Actron 9040 - che ci dovrebbe aiutare nei primi passi durante l'uso Actron 9040
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Actron 9040
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Actron 9040 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Actron 9040?

Utilizza il modulo sottostante

Se non hai risolto il problema con Actron 9040 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Actron 9040 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)