  • Watlow Electric RUI/Gateway - page 1

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 1 FM 4/08 Configuring the EZ-ZONE ® RUI/Gateway 1. This White Paper is not m eant to be an exhaustive step-by-st ep discussion in configuring the RUI/Gateway, ...

  • Watlow Electric RUI/Gateway - page 2

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 2 FM 4/08 3. Some notables regarding the graphic above. In the steps that follow we are going to focus on four of the prompt s shown: a. Modbus ® Enable ( Mb;E ...

  • Watlow Electric RUI/Gateway - page 3

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 3 FM 4/08 9. Provide a name for the channel. 10. In this example the device driv er selected will be “Modbus Ethernet”. ...

  • Watlow Electric RUI/Gateway - page 4

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 4 FM 4/08 11. Select the appropriate hardware (network adapter) used on the network. 12. Next, select the appropriat e write optimization method. ...

  • Watlow Electric RUI/Gateway - page 5

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 5 FM 4/08 13. The next selection allows for multiple master s on the network. When mult iple masters exist on a network talking (reading & writ ing) to the ...

  • Watlow Electric RUI/Gateway - page 6

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 6 FM 4/08 15. Once the channel configuration is complete it is now time to configure a device (RUI/Gateway). 16. Select the Modbus ® driver. ...

  • Watlow Electric RUI/Gateway - page 7

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 7 FM 4/08 17. Recall that in steps 1-3 it was said that there ar e other configuration st eps that need to be addressed that are not covered in this paper. As a ...

  • Watlow Electric RUI/Gateway - page 8

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 8 FM 4/08 19. If communications fail between KEPServer EX and RUI/Gateway stop polling device. 20. Generate unique input / output (I /O) tags for the RUI/Gatewa ...

  • Watlow Electric RUI/Gateway - page 9

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 9 FM 4/08 21. Use the defaults for port number and IP protocol. 22. Use the defaults as shown. ...

  • Watlow Electric RUI/Gateway - page 10

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 10 FM 4/08 23. The graphic below sh ows the default Modbus ® word order which also represents the default Modbus ® word order for the RUI/Gateway (Low/High). ...

  • Watlow Electric RUI/Gateway - page 11

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 11 FM 4/08 25. KEPServerEX allows for impor ted tags via a text file. 26. Any tag returning an except ion error will no longer be polle d. ...

  • Watlow Electric RUI/Gateway - page 12

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 12 FM 4/08 27. This concludes the device (RUI/Gateway) configuration. 28. Tag creation. In step 5 some prompts were shown indicating fu rther explanation would ...

  • Watlow Electric RUI/Gateway - page 13

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 13 FM 4/08 each: PV1 of PM1 = 400361 (offset = 0) PV1 of PM2 = 405361 (offset = 5000) PV1 of PM3 = 410361 (offset = 10000) PV1 of PM4 = 415361 (offset = 15000) ...

  • Watlow Electric RUI/Gateway - page 14

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 14 FM 4/08 30. To create similar tags for PV2 - PV4 simply click on the duplicate ic on (circle) and change the fields accordingly (squares). 31. Once each of t ...

  • Watlow Electric RUI/Gateway - page 15

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 15 FM 4/08 said, look closely at the addresses given in defining the CLSP for each of the four PM controls. 33. In the screen shot above we now see a series of ...

  • Watlow Electric RUI/Gateway - page 16

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 16 FM 4/08 34. To better understand the follo wing discussion and examples download and read the section entitled “User Programmable Memory Blocks” found in ...

  • Watlow Electric RUI/Gateway - page 17

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 17 FM 4/08 36. In the screen shot that follows one can see t he factory defaults for the Assembly Definition Addresses (block of 80 words) as they are bei ng re ...

  • Watlow Electric RUI/Gateway - page 18

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 18 FM 4/08 38. Changing an element in the assembly is EZ. A new tag was created as shown below. Notice the address identified as well as the data type. ...

  • Watlow Electric RUI/Gateway - page 19

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 19 FM 4/08 39. The address shown above represents pointer 12 as shown in the EZ-ZONE ® PM Communications user manual under the s ub-heading of “User Programm ...

  • Watlow Electric RUI/Gateway - page 20

    RUI/Gateway & Modbus ® TCP Configuration & Programming Exampl e Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 20 FM 4/08 42. Lastly, in the screen shot below, notice that the 12 th pointer has indeed been changed to Idle Set Point (circle) and the tag created to reflect ...

Manufacturer Watlow Electric Category Network Card

Documents that we receive from a manufacturer of a Watlow Electric RUI/Gateway can be divided into several groups. They are, among others:
- Watlow Electric technical drawings
- RUI/Gateway manuals
- Watlow Electric product data sheets
- information booklets
- or energy labels Watlow Electric RUI/Gateway
All of them are important, but the most important information from the point of view of use of the device are in the user manual Watlow Electric RUI/Gateway.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Watlow Electric RUI/Gateway, service manual, brief instructions and user manuals Watlow Electric RUI/Gateway. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Watlow Electric RUI/Gateway.

A complete manual for the device Watlow Electric RUI/Gateway, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Watlow Electric RUI/Gateway by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Watlow Electric RUI/Gateway.

A complete Watlow Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Watlow Electric RUI/Gateway - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Watlow Electric RUI/Gateway, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Watlow Electric RUI/Gateway, that we can find in the current document
3. Tips how to use the basic functions of the device Watlow Electric RUI/Gateway - which should help us in our first steps of using Watlow Electric RUI/Gateway
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Watlow Electric RUI/Gateway
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Watlow Electric RUI/Gateway in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Watlow Electric RUI/Gateway?

Use the form below

If you did not solve your problem by using a manual Watlow Electric RUI/Gateway, ask a question using the form below. If a user had a similar problem with Watlow Electric RUI/Gateway it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)