Manual de instrucciones SPX Cooling Technologies 160

12 de páginas 0.83 mb
Descargar

Pasar a la página of 12

Summary
  • SPX Cooling Technologies 160 - page 1

    / Mar le y Class 160 Cooling T ower / ...

  • SPX Cooling Technologies 160 - page 2

    2 / The Mar ley Dif f er ence / Y ou’ll enjoy single sour ce responsibility and reliability because we design and manufacture virtually all major cooling tower components. All Marley components are designed and selected to be part of an integrated system . For example, the spray pattern from nozzles and the pr essure dr op through drift eliminato ...

  • SPX Cooling Technologies 160 - page 3

    3 / Constr uction and Components / ■ Fill/Louvers/Drift Eliminators Marley high-performance lm ll is the heart of every Class 160 tower . A r epeating chevron patter n provides the wetted surface and air turbulence necessary for proper heat transfer , while minimizing resistance to airow so you’ll save on fan power . Molded pr otrusion ...

  • SPX Cooling Technologies 160 - page 4

    4 Class 160 towers offer the benets of adjustable pitch propeller type fans. All fans used on Class 160 towers include hollow GRE (glass-reinfor ced epoxy) blades and epoxy-coated cast iron or galvanized steel hubs. Blades ar e adjustable in pitch, so you can take full advantage of rated horsepower or adjust the pitch to compensate for unusual j ...

  • SPX Cooling Technologies 160 - page 5

    5 The primary structural elements of all Class 160 towers are the nominal 4 ″ x 4 ″ columns spaced on 4 ′ -0 ″ longitudinal centers. A system of nominal 4 ″ x 4 ″ tower diagonals carries loads in both tension and compression to heavy-duty hot dip galvanized steel anchor plates. Pressur e-treated Douglas Fir is the standar d material for ...

  • SPX Cooling Technologies 160 - page 6

    6 / Oper ating and Envir onmental Consider ations / Caution The cooling tower must be located at such distance and direction to avoid the possibility of contaminated tower discharge air being drawn into building fresh air intake ducts. The purchaser should obtain the services of a Licensed Professional Engineer or Registered Architect to certify th ...

  • SPX Cooling Technologies 160 - page 7

    7 / T o wer Sc hematic / 1. Last number of model indicates number of cells. Change as appropriate for your selection. Primary engineering data is per cell. 2. Fan hp is usually less than shown here. 3. Height shown is from base of tower columns to fan deck. W ood basin, if used, elevates tower 6 ¹⁄₄ ″ . If concrete basin is used, subtract 1 ...

  • SPX Cooling Technologies 160 - page 8

    8 / St eel Basin Support / 1. Use this bulletin for preliminary layouts only . All dimensions show column locations, not anchor bolt locations. Obtain current drawings from your Marley sales r epresentative befor e designing supports. 2. Other contractors or purchaser must design and er ect support- ing steel. 3. If steel beams are used, they must ...

  • SPX Cooling Technologies 160 - page 9

    9 1. Use this bulletin for preliminary layouts only . Do not use for construction. Obtain current drawings fr om your Marley sales repr esentative. Concrete basin design and construction ar e by other contractors or purchaser . 2. Operating weight is total wet operating weight of tower only , excluding water in concrete basin. 3. Maintain at least ...

  • SPX Cooling Technologies 160 - page 10

    10 / Inlet Piping Plan / G BASE OF T OWER COL. INLET C L B DIA. FLOW CONTROL V AL VE AND CROSSO VER PIPE R E W O 4 L E D O - - 0 ' L L E # R E P S N O I S N E M I $ ! " # $ % & '                             q   q   q   q   ...

  • SPX Cooling Technologies 160 - page 11

    11 ■ Cell Partition Options Every Class 160 tower includes plenum partitions and hot water distribution basin partitions between adjacent cells. Plenum partitions keep air from entering an operating cell through an adjacent idle fan—assuring consistent thermal performance. Basin partitions let you inspect and clean individual basins while the r ...

  • SPX Cooling Technologies 160 - page 12

    / A v ailable Options / Accessory Description and Remarks Accessory Description and Remarks Fan Cylinder Extension Optional ared fan cylinder extensions improve fan efciency to r educe your operating costs. Cell Partition Extra partitions between fan cells for specic operating considerations. See page 11. Vibration Limit Switches Air Inlet ...

Fabricante SPX Cooling Technologies Categoría Humidifier

Los documentos del dispositivo SPX Cooling Technologies 160 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos SPX Cooling Technologies
- manuales de instrucciones 160
- hojas de producto SPX Cooling Technologies
- folletos informativos
- o etiquetas energéticas SPX Cooling Technologies 160
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones SPX Cooling Technologies 160.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje SPX Cooling Technologies 160, instrucciones de servicio, instrucciones cortas o instrucciones de usuario SPX Cooling Technologies 160. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto SPX Cooling Technologies 160.

El manual de instrucciones del dispositivo SPX Cooling Technologies 160, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar SPX Cooling Technologies 160. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de SPX Cooling Technologies 160.

El manual de instrucciones completo de SPX Cooling Technologies debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual SPX Cooling Technologies 160 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice SPX Cooling Technologies 160, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de SPX Cooling Technologies 160 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo SPX Cooling Technologies 160 - que deben facilitarnos los primeros pasos durante el uso de SPX Cooling Technologies 160
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con SPX Cooling Technologies 160
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de SPX Cooling Technologies 160 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de SPX Cooling Technologies 160?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con SPX Cooling Technologies 160, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con SPX Cooling Technologies 160 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)