SPX Cooling Technologies 160の取扱説明書

12ページ 0.83 mb
ダウンロード

ページに移動 of 12

Summary
  • SPX Cooling Technologies 160 - page 1

    / Mar le y Class 160 Cooling T ower / ...

  • SPX Cooling Technologies 160 - page 2

    2 / The Mar ley Dif f er ence / Y ou’ll enjoy single sour ce responsibility and reliability because we design and manufacture virtually all major cooling tower components. All Marley components are designed and selected to be part of an integrated system . For example, the spray pattern from nozzles and the pr essure dr op through drift eliminato ...

  • SPX Cooling Technologies 160 - page 3

    3 / Constr uction and Components / ■ Fill/Louvers/Drift Eliminators Marley high-performance lm ll is the heart of every Class 160 tower . A r epeating chevron patter n provides the wetted surface and air turbulence necessary for proper heat transfer , while minimizing resistance to airow so you’ll save on fan power . Molded pr otrusion ...

  • SPX Cooling Technologies 160 - page 4

    4 Class 160 towers offer the benets of adjustable pitch propeller type fans. All fans used on Class 160 towers include hollow GRE (glass-reinfor ced epoxy) blades and epoxy-coated cast iron or galvanized steel hubs. Blades ar e adjustable in pitch, so you can take full advantage of rated horsepower or adjust the pitch to compensate for unusual j ...

  • SPX Cooling Technologies 160 - page 5

    5 The primary structural elements of all Class 160 towers are the nominal 4 ″ x 4 ″ columns spaced on 4 ′ -0 ″ longitudinal centers. A system of nominal 4 ″ x 4 ″ tower diagonals carries loads in both tension and compression to heavy-duty hot dip galvanized steel anchor plates. Pressur e-treated Douglas Fir is the standar d material for ...

  • SPX Cooling Technologies 160 - page 6

    6 / Oper ating and Envir onmental Consider ations / Caution The cooling tower must be located at such distance and direction to avoid the possibility of contaminated tower discharge air being drawn into building fresh air intake ducts. The purchaser should obtain the services of a Licensed Professional Engineer or Registered Architect to certify th ...

  • SPX Cooling Technologies 160 - page 7

    7 / T o wer Sc hematic / 1. Last number of model indicates number of cells. Change as appropriate for your selection. Primary engineering data is per cell. 2. Fan hp is usually less than shown here. 3. Height shown is from base of tower columns to fan deck. W ood basin, if used, elevates tower 6 ¹⁄₄ ″ . If concrete basin is used, subtract 1 ...

  • SPX Cooling Technologies 160 - page 8

    8 / St eel Basin Support / 1. Use this bulletin for preliminary layouts only . All dimensions show column locations, not anchor bolt locations. Obtain current drawings from your Marley sales r epresentative befor e designing supports. 2. Other contractors or purchaser must design and er ect support- ing steel. 3. If steel beams are used, they must ...

  • SPX Cooling Technologies 160 - page 9

    9 1. Use this bulletin for preliminary layouts only . Do not use for construction. Obtain current drawings fr om your Marley sales repr esentative. Concrete basin design and construction ar e by other contractors or purchaser . 2. Operating weight is total wet operating weight of tower only , excluding water in concrete basin. 3. Maintain at least ...

  • SPX Cooling Technologies 160 - page 10

    10 / Inlet Piping Plan / G BASE OF T OWER COL. INLET C L B DIA. FLOW CONTROL V AL VE AND CROSSO VER PIPE R E W O 4 L E D O - - 0 ' L L E # R E P S N O I S N E M I $ ! " # $ % & '                             q   q   q   q   ...

  • SPX Cooling Technologies 160 - page 11

    11 ■ Cell Partition Options Every Class 160 tower includes plenum partitions and hot water distribution basin partitions between adjacent cells. Plenum partitions keep air from entering an operating cell through an adjacent idle fan—assuring consistent thermal performance. Basin partitions let you inspect and clean individual basins while the r ...

  • SPX Cooling Technologies 160 - page 12

    / A v ailable Options / Accessory Description and Remarks Accessory Description and Remarks Fan Cylinder Extension Optional ared fan cylinder extensions improve fan efciency to r educe your operating costs. Cell Partition Extra partitions between fan cells for specic operating considerations. See page 11. Vibration Limit Switches Air Inlet ...

メーカー SPX Cooling Technologies カテゴリー Humidifier

SPX Cooling Technologies 160のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 160の取扱説明書
- SPX Cooling Technologiesの製品カード
- パンフレット
- またはSPX Cooling Technologies 160の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、SPX Cooling Technologies 160の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、SPX Cooling Technologies 160の取り付け説明書、サービスマニュアル、簡易説明書、またはSPX Cooling Technologies 160のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、SPX Cooling Technologies 160の製品を使用するにあたって最も人気のある説明書を閲覧できます。

SPX Cooling Technologies 160デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSPX Cooling Technologies 160を使用するのを助ける技術的文書のことです。説明書は通常、全てのSPX Cooling Technologies 160ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

SPX Cooling Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. SPX Cooling Technologies 160の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSPX Cooling Technologies 160の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。SPX Cooling Technologies 160に関してこのドキュメントで見つけることができる全てのヒントの目次
3. SPX Cooling Technologies 160デバイスの基本機能を使うにあたってのヒント。 SPX Cooling Technologies 160のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。SPX Cooling Technologies 160に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSPX Cooling Technologies 160のメーカー/サービスへの連絡先に関する情報。

SPX Cooling Technologies 160についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSPX Cooling Technologies 160の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSPX Cooling Technologies 160で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)