  • SPX Cooling Technologies 160 - page 1

    / Mar le y Class 160 Cooling T ower / ...

  • SPX Cooling Technologies 160 - page 2

    2 / The Mar ley Dif f er ence / Y ou’ll enjoy single sour ce responsibility and reliability because we design and manufacture virtually all major cooling tower components. All Marley components are designed and selected to be part of an integrated system . For example, the spray pattern from nozzles and the pr essure dr op through drift eliminato ...

  • SPX Cooling Technologies 160 - page 3

    3 / Constr uction and Components / ■ Fill/Louvers/Drift Eliminators Marley high-performance lm ll is the heart of every Class 160 tower . A r epeating chevron patter n provides the wetted surface and air turbulence necessary for proper heat transfer , while minimizing resistance to airow so you’ll save on fan power . Molded pr otrusion ...

  • SPX Cooling Technologies 160 - page 4

    4 Class 160 towers offer the benets of adjustable pitch propeller type fans. All fans used on Class 160 towers include hollow GRE (glass-reinfor ced epoxy) blades and epoxy-coated cast iron or galvanized steel hubs. Blades ar e adjustable in pitch, so you can take full advantage of rated horsepower or adjust the pitch to compensate for unusual j ...

  • SPX Cooling Technologies 160 - page 5

    5 The primary structural elements of all Class 160 towers are the nominal 4 ″ x 4 ″ columns spaced on 4 ′ -0 ″ longitudinal centers. A system of nominal 4 ″ x 4 ″ tower diagonals carries loads in both tension and compression to heavy-duty hot dip galvanized steel anchor plates. Pressur e-treated Douglas Fir is the standar d material for ...

  • SPX Cooling Technologies 160 - page 6

    6 / Oper ating and Envir onmental Consider ations / Caution The cooling tower must be located at such distance and direction to avoid the possibility of contaminated tower discharge air being drawn into building fresh air intake ducts. The purchaser should obtain the services of a Licensed Professional Engineer or Registered Architect to certify th ...

  • SPX Cooling Technologies 160 - page 7

    7 / T o wer Sc hematic / 1. Last number of model indicates number of cells. Change as appropriate for your selection. Primary engineering data is per cell. 2. Fan hp is usually less than shown here. 3. Height shown is from base of tower columns to fan deck. W ood basin, if used, elevates tower 6 ¹⁄₄ ″ . If concrete basin is used, subtract 1 ...

  • SPX Cooling Technologies 160 - page 8

    8 / St eel Basin Support / 1. Use this bulletin for preliminary layouts only . All dimensions show column locations, not anchor bolt locations. Obtain current drawings from your Marley sales r epresentative befor e designing supports. 2. Other contractors or purchaser must design and er ect support- ing steel. 3. If steel beams are used, they must ...

  • SPX Cooling Technologies 160 - page 9

    9 1. Use this bulletin for preliminary layouts only . Do not use for construction. Obtain current drawings fr om your Marley sales repr esentative. Concrete basin design and construction ar e by other contractors or purchaser . 2. Operating weight is total wet operating weight of tower only , excluding water in concrete basin. 3. Maintain at least ...

  • SPX Cooling Technologies 160 - page 10

    10 / Inlet Piping Plan / G BASE OF T OWER COL. INLET C L B DIA. FLOW CONTROL V AL VE AND CROSSO VER PIPE R E W O 4 L E D O - - 0 ' L L E # R E P S N O I S N E M I $ ! " # $ % & '                             q   q   q   q   ...

  • SPX Cooling Technologies 160 - page 11

    11 ■ Cell Partition Options Every Class 160 tower includes plenum partitions and hot water distribution basin partitions between adjacent cells. Plenum partitions keep air from entering an operating cell through an adjacent idle fan—assuring consistent thermal performance. Basin partitions let you inspect and clean individual basins while the r ...

  • SPX Cooling Technologies 160 - page 12

    / A v ailable Options / Accessory Description and Remarks Accessory Description and Remarks Fan Cylinder Extension Optional ared fan cylinder extensions improve fan efciency to r educe your operating costs. Cell Partition Extra partitions between fan cells for specic operating considerations. See page 11. Vibration Limit Switches Air Inlet ...

Производитель SPX Cooling Technologies Категория Humidifier

Документы, которые мы получаем от производителя устройства SPX Cooling Technologies 160 мы можем разделить на несколько групп. Это в частности:
- технические чертежи SPX Cooling Technologies
- инструкции обслуживания 160
- паспорта изделия SPX Cooling Technologies
- информационные брошюры
- энергетические этикетки SPX Cooling Technologies 160
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания SPX Cooling Technologies 160.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа SPX Cooling Technologies 160, инструкции обслуживания, короткие инструкции или инструкции пользователя SPX Cooling Technologies 160. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия SPX Cooling Technologies 160.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства SPX Cooling Technologies 160, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании SPX Cooling Technologies 160 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей SPX Cooling Technologies 160.

Полная инструкция обслуживания SPX Cooling Technologies, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией SPX Cooling Technologies 160 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания SPX Cooling Technologies 160, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся SPX Cooling Technologies 160, которое найдем в данном документе
3. Советы по использованию основных функций устройства SPX Cooling Technologies 160 - которые должны облегчить нам первые шаги во время использования SPX Cooling Technologies 160
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем SPX Cooling Technologies 160
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра SPX Cooling Technologies 160 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся SPX Cooling Technologies 160?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с SPX Cooling Technologies 160, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с SPX Cooling Technologies 160 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)