    / Mar le y Class 160 Cooling T ower / ...

  • SPX Cooling Technologies 160 - page 2

    2 / The Mar ley Dif f er ence / Y ou’ll enjoy single sour ce responsibility and reliability because we design and manufacture virtually all major cooling tower components. All Marley components are designed and selected to be part of an integrated system . For example, the spray pattern from nozzles and the pr essure dr op through drift eliminato ...

  • SPX Cooling Technologies 160 - page 3

    3 / Constr uction and Components / ■ Fill/Louvers/Drift Eliminators Marley high-performance lm ll is the heart of every Class 160 tower . A r epeating chevron patter n provides the wetted surface and air turbulence necessary for proper heat transfer , while minimizing resistance to airow so you’ll save on fan power . Molded pr otrusion ...

  • SPX Cooling Technologies 160 - page 4

    4 Class 160 towers offer the benets of adjustable pitch propeller type fans. All fans used on Class 160 towers include hollow GRE (glass-reinfor ced epoxy) blades and epoxy-coated cast iron or galvanized steel hubs. Blades ar e adjustable in pitch, so you can take full advantage of rated horsepower or adjust the pitch to compensate for unusual j ...

  • SPX Cooling Technologies 160 - page 5

    5 The primary structural elements of all Class 160 towers are the nominal 4 ″ x 4 ″ columns spaced on 4 ′ -0 ″ longitudinal centers. A system of nominal 4 ″ x 4 ″ tower diagonals carries loads in both tension and compression to heavy-duty hot dip galvanized steel anchor plates. Pressur e-treated Douglas Fir is the standar d material for ...

  • SPX Cooling Technologies 160 - page 6

    6 / Oper ating and Envir onmental Consider ations / Caution The cooling tower must be located at such distance and direction to avoid the possibility of contaminated tower discharge air being drawn into building fresh air intake ducts. The purchaser should obtain the services of a Licensed Professional Engineer or Registered Architect to certify th ...

  • SPX Cooling Technologies 160 - page 7

    7 / T o wer Sc hematic / 1. Last number of model indicates number of cells. Change as appropriate for your selection. Primary engineering data is per cell. 2. Fan hp is usually less than shown here. 3. Height shown is from base of tower columns to fan deck. W ood basin, if used, elevates tower 6 ¹⁄₄ ″ . If concrete basin is used, subtract 1 ...

  • SPX Cooling Technologies 160 - page 8

    8 / St eel Basin Support / 1. Use this bulletin for preliminary layouts only . All dimensions show column locations, not anchor bolt locations. Obtain current drawings from your Marley sales r epresentative befor e designing supports. 2. Other contractors or purchaser must design and er ect support- ing steel. 3. If steel beams are used, they must ...

  • SPX Cooling Technologies 160 - page 9

    9 1. Use this bulletin for preliminary layouts only . Do not use for construction. Obtain current drawings fr om your Marley sales repr esentative. Concrete basin design and construction ar e by other contractors or purchaser . 2. Operating weight is total wet operating weight of tower only , excluding water in concrete basin. 3. Maintain at least ...

  • SPX Cooling Technologies 160 - page 10

    10 / Inlet Piping Plan / G BASE OF T OWER COL. INLET C L B DIA. FLOW CONTROL V AL VE AND CROSSO VER PIPE R E W O 4 L E D O - - 0 ' L L E # R E P S N O I S N E M I $ ! " # $ % & '                             q   q   q   q   ...

  • SPX Cooling Technologies 160 - page 11

    11 ■ Cell Partition Options Every Class 160 tower includes plenum partitions and hot water distribution basin partitions between adjacent cells. Plenum partitions keep air from entering an operating cell through an adjacent idle fan—assuring consistent thermal performance. Basin partitions let you inspect and clean individual basins while the r ...

  • SPX Cooling Technologies 160 - page 12

    / A v ailable Options / Accessory Description and Remarks Accessory Description and Remarks Fan Cylinder Extension Optional ared fan cylinder extensions improve fan efciency to r educe your operating costs. Cell Partition Extra partitions between fan cells for specic operating considerations. See page 11. Vibration Limit Switches Air Inlet ...

Fabricant SPX Cooling Technologies Catégorie Humidifier

Les documents que nous recevons du fabricant de l'appareilSPX Cooling Technologies 160 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques SPX Cooling Technologies
- manuels d’utilisations 160
- fiches produit SPX Cooling Technologies
- dépliants
- ou étiquettes-énergie SPX Cooling Technologies 160
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation SPX Cooling Technologies 160.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation SPX Cooling Technologies 160, manuels d’entretien, brefs manuels ou manuels de l’utilisateur SPX Cooling Technologies 160. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit SPX Cooling Technologies 160.

Manuel d’utilisation complet de l’appareil SPX Cooling Technologies 160, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser SPX Cooling Technologies 160 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs SPX Cooling Technologies 160.

Le manuel d’utilisation complet SPX Cooling Technologies, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel SPX Cooling Technologies 160 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières SPX Cooling Technologies 160, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSPX Cooling Technologies 160 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil SPX Cooling Technologies 160 - qui devraient nous aider dans les premières étapes lors de l'utilisation SPX Cooling Technologies 160
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de SPX Cooling Technologies 160
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service SPX Cooling Technologies 160 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de SPX Cooling Technologies 160?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec SPX Cooling Technologies 160, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec SPX Cooling Technologies 160 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)