Manual SPX Cooling Technologies 160

12 pages 0.83 mb
Download

Go to site of 12

Summary
  • SPX Cooling Technologies 160 - page 1

    / Mar le y Class 160 Cooling T ower / ...

  • SPX Cooling Technologies 160 - page 2

    2 / The Mar ley Dif f er ence / Y ou’ll enjoy single sour ce responsibility and reliability because we design and manufacture virtually all major cooling tower components. All Marley components are designed and selected to be part of an integrated system . For example, the spray pattern from nozzles and the pr essure dr op through drift eliminato ...

  • SPX Cooling Technologies 160 - page 3

    3 / Constr uction and Components / ■ Fill/Louvers/Drift Eliminators Marley high-performance lm ll is the heart of every Class 160 tower . A r epeating chevron patter n provides the wetted surface and air turbulence necessary for proper heat transfer , while minimizing resistance to airow so you’ll save on fan power . Molded pr otrusion ...

  • SPX Cooling Technologies 160 - page 4

    4 Class 160 towers offer the benets of adjustable pitch propeller type fans. All fans used on Class 160 towers include hollow GRE (glass-reinfor ced epoxy) blades and epoxy-coated cast iron or galvanized steel hubs. Blades ar e adjustable in pitch, so you can take full advantage of rated horsepower or adjust the pitch to compensate for unusual j ...

  • SPX Cooling Technologies 160 - page 5

    5 The primary structural elements of all Class 160 towers are the nominal 4 ″ x 4 ″ columns spaced on 4 ′ -0 ″ longitudinal centers. A system of nominal 4 ″ x 4 ″ tower diagonals carries loads in both tension and compression to heavy-duty hot dip galvanized steel anchor plates. Pressur e-treated Douglas Fir is the standar d material for ...

  • SPX Cooling Technologies 160 - page 6

    6 / Oper ating and Envir onmental Consider ations / Caution The cooling tower must be located at such distance and direction to avoid the possibility of contaminated tower discharge air being drawn into building fresh air intake ducts. The purchaser should obtain the services of a Licensed Professional Engineer or Registered Architect to certify th ...

  • SPX Cooling Technologies 160 - page 7

    7 / T o wer Sc hematic / 1. Last number of model indicates number of cells. Change as appropriate for your selection. Primary engineering data is per cell. 2. Fan hp is usually less than shown here. 3. Height shown is from base of tower columns to fan deck. W ood basin, if used, elevates tower 6 ¹⁄₄ ″ . If concrete basin is used, subtract 1 ...

  • SPX Cooling Technologies 160 - page 8

    8 / St eel Basin Support / 1. Use this bulletin for preliminary layouts only . All dimensions show column locations, not anchor bolt locations. Obtain current drawings from your Marley sales r epresentative befor e designing supports. 2. Other contractors or purchaser must design and er ect support- ing steel. 3. If steel beams are used, they must ...

  • SPX Cooling Technologies 160 - page 9

    9 1. Use this bulletin for preliminary layouts only . Do not use for construction. Obtain current drawings fr om your Marley sales repr esentative. Concrete basin design and construction ar e by other contractors or purchaser . 2. Operating weight is total wet operating weight of tower only , excluding water in concrete basin. 3. Maintain at least ...

  • SPX Cooling Technologies 160 - page 10

    10 / Inlet Piping Plan / G BASE OF T OWER COL. INLET C L B DIA. FLOW CONTROL V AL VE AND CROSSO VER PIPE R E W O 4 L E D O - - 0 ' L L E # R E P S N O I S N E M I $ ! " # $ % & '                             q   q   q   q   ...

  • SPX Cooling Technologies 160 - page 11

    11 ■ Cell Partition Options Every Class 160 tower includes plenum partitions and hot water distribution basin partitions between adjacent cells. Plenum partitions keep air from entering an operating cell through an adjacent idle fan—assuring consistent thermal performance. Basin partitions let you inspect and clean individual basins while the r ...

  • SPX Cooling Technologies 160 - page 12

    / A v ailable Options / Accessory Description and Remarks Accessory Description and Remarks Fan Cylinder Extension Optional ared fan cylinder extensions improve fan efciency to r educe your operating costs. Cell Partition Extra partitions between fan cells for specic operating considerations. See page 11. Vibration Limit Switches Air Inlet ...

Manufacturer SPX Cooling Technologies Category Humidifier

Documents that we receive from a manufacturer of a SPX Cooling Technologies 160 can be divided into several groups. They are, among others:
- SPX Cooling Technologies technical drawings
- 160 manuals
- SPX Cooling Technologies product data sheets
- information booklets
- or energy labels SPX Cooling Technologies 160
All of them are important, but the most important information from the point of view of use of the device are in the user manual SPX Cooling Technologies 160.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals SPX Cooling Technologies 160, service manual, brief instructions and user manuals SPX Cooling Technologies 160. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product SPX Cooling Technologies 160.

A complete manual for the device SPX Cooling Technologies 160, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use SPX Cooling Technologies 160 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of SPX Cooling Technologies 160.

A complete SPX Cooling Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual SPX Cooling Technologies 160 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the SPX Cooling Technologies 160, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the SPX Cooling Technologies 160, that we can find in the current document
3. Tips how to use the basic functions of the device SPX Cooling Technologies 160 - which should help us in our first steps of using SPX Cooling Technologies 160
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with SPX Cooling Technologies 160
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of SPX Cooling Technologies 160 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning SPX Cooling Technologies 160?

Use the form below

If you did not solve your problem by using a manual SPX Cooling Technologies 160, ask a question using the form below. If a user had a similar problem with SPX Cooling Technologies 160 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)