  • Goodman Mfg SSZ160361A - page 1

    SSZ 16 SEER S plit System Heat Pumps • Refer to Service Manual RS6200005 for installation, op- eration, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. RT6214002 Rev. 2 September 2007 TECHNICAL INFORMA TION MANUA ...

  • Goodman Mfg SSZ160361A - page 2

    PRODUCT IDENTIFICA TION 2 The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. WARNING WARNING WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to d ...

  • Goodman Mfg SSZ160361A - page 3

    PRODUCT IDENTIFICA TION 3 WARNING WARNING WARNING WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serio ...

  • Goodman Mfg SSZ160361A - page 4

    PRODUCT DESIGN 4 SSZ16 models are available in 2, 3, 4 and 5 ton sizes and use R-410A refrigerant. They are designed for 208/230 volt single phase applications. The condenser air is pulled through the condenser coil by a direct drive propeller fan. This condenser air is then dis- charged out of the top of the cabinet. These units are designed for f ...

  • Goodman Mfg SSZ160361A - page 5

    HEA T PUMP SPECIFICA TIONS 5 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial ...

  • Goodman Mfg SSZ160361A - page 6

    6 COOLING PERFORMANCE DA T A SSZ160241A* EXPA NDED PERFORMA NCE DA TA COOLIN G OPERA TION MO DE L: SSZ160241A* / CA *F3636 *6A * + TXV / MBE1600* *- 1 Design Sub cooling 7 ± 2 °F @ the liqui d ser vice valv e, A RI 95 test con di tions Outd oor A mbient Temper atur e 65 75 85 95 105 115 Ente ring Indo or W et Bulb Tem pera ture IDB A i rflow 59 6 ...

  • Goodman Mfg SSZ160361A - page 7

    7 COOLING PERFORMANCE DA T A SSZ160241A* EXPA NDED PERFO RMA NCE DA T A COOLI NG O PERATI ON MODEL: SSZ160 24 1A* / CA *F3636* 6A * + TXV / MBE1600* *-1 Design S ubco oling 7 ± 2 °F @ the liquid service valve, A RI 95 test condi ti ons Outdoor Ambient Tempera ture 65 75 85 95 105 115 Entering I ndoor W et Bulb Temperature I D B * A i r f l o w 5 ...

  • Goodman Mfg SSZ160361A - page 8

    8 COOLING PERFORMANCE DA T A EXPA NDED PERFORM A NCE DA TA COOLI NG O PERATI ON MODEL: SSZ160361A * / CA*F4860*6A * + TXV / MBE2000**- 1 Design Subcooling 9 ± 3 °F @ the liqui d service valve, A RI 95 test condit i ons Outdoo r Ambient Temperat u re 65 75 85 95 105 115 Ente ring Indoo r Wet Bulb Tempe rature IDB A ir flow 59 63 67 71 59 6 3 67 71 ...

  • Goodman Mfg SSZ160361A - page 9

    9 COOLING PERFORMANCE DA T A EXPA NDED PERFORM A NCE DA TA COOLI NG O PERATI ON MODEL: SSZ160361A * / CA*F4860*6A * + TXV / M BE2000**-1 Design Subcooli ng 9 ±3 °F @ the liqu id servi ce valve, A RI 95 test condit i ons Outdoo r Ambient Temperat u re 65 75 85 95 105 115 Ente ring Indoo r Wet Bulb Tempe rature I D B * A i r f l o w 5 9 6 3 6 77 1 ...

  • Goodman Mfg SSZ160361A - page 10

    10 COOLING PERFORMANCE DA T A SSZ160481A* EXPANDED PERFORMANCE DA TA COOLIN G OPERA TION M ODEL: SSZ160481A * / CA* F4860*6A * + TXV / MBE200 0**-1 Design Su bcoolin g 7 ± 2 ° F @ t he liqu id service valv e, A RI 95 test condi tion s Outdoor Ambient Temper ature 65 75 85 95 105 115 Ente ring Indo or W et Bulb T emperat ure I D B * A i r f l o w ...

  • Goodman Mfg SSZ160361A - page 11

    11 COOLING PERFORMANCE DA T A SSZ160481A* EXPANDED PERFORMANCE DA TA COOLIN G OPERA TION M ODEL: SSZ160481A* / CA*F4860*6A * + TXV / MBE2000**- 1 Design Su bcooling 7 ± 2 ° F @ the liquid service valve, A R I 95 test condi tion s Outdoor Ambient Temperature 65 75 85 95 105 115 Ente ring Indo or Wet Bulb T empera ture I D B * A i r f l o w 5 96 36 ...

  • Goodman Mfg SSZ160361A - page 12

    12 COOLING PERFORMANCE DA T A SSZ160601A* EXPA NDED PERFORMANCE DA TA COOLING OP ERA TIO N MODEL: SSZ160601A* / CA *F 4860*6A* + T XV / MBE2000**-1 Design Subcool in g 7 ± 2 °F @ the liquid service valve, ARI 95 test condi tions Outdoor Ambient Temperature 65 75 85 95 105 115 Enter ing In door W et Bulb Tem perature I D B * A i r f l o w 5 96 36 ...

  • Goodman Mfg SSZ160361A - page 13

    13 COOLING PERFORMANCE DA T A SSZ160601A* EXPA NDED PERFORMANCE DA TA COOLIN G OPERATION MODEL: SSZ160601A* / CA *F 4860*6A* + T XV / MBE2000**-1 Design Subcool in g 7 ± 2 °F @ the liquid service valv e, A RI 95 test condi tions Outdoor Ambient Temperature 65 75 85 95 105 115 Enter ing In door W et Bulb Tem perature I D B * A i r f l o w 5 96 36 ...

  • Goodman Mfg SSZ160361A - page 14

    14 PERFORMANCE DA T A Outdoor Temp. ° F. Total Btuh Sensible Btuh Laten t Btuh Total Watts 75° 25,200 18,540 6,660 1,645 80° 24,900 18,553 6,347 1,697 85° 24,600 18,559 6,041 1,749 90° 24,300 18,628 5,672 1,795 95° 24,000 18,690 5,310 1,841 100° 23,400 18, 568 4,832 1,880 105° 22,800 18, 428 4,372 1,919 110° 21,960 17, 824 4,136 1,952 115? ...

  • Goodman Mfg SSZ160361A - page 15

    15 SPLIT SYSTEM HEA TING PERFORMANCE High pres sure is m easured a t the liquid service valve (the smaller valve). AMPS = Outdoor un it am ps (comp. +fan) Low pressure is mea sured at t he gauge port connecti on. KW = Total system power Calculat ions ar e based on n ominal CFM and 70 ° F indoor d ry bulb. *Note: Shaded area is ARI Rating Condition ...

  • Goodman Mfg SSZ160361A - page 16

    16 HEA TING SPECIFICA TIONS *To obtain BTU capacity of unit with KW of auxiliary heat, multiply by 1000 (Example: 39.01 x 1000 = 39,010 BTU) capacit y btuh c.o. p. 4.8 9. 6 14.4 19.2 65 30.17 4.93 46.55 62.93 79.32 95.70 60 28.56 4.76 44.94 61.32 77.71 94.09 55 26.88 4.57 43.26 59.64 76.03 92.41 50 25.13 4.37 41.51 57.89 74.28 90.66 45 23.26 4.13 3 ...

  • Goodman Mfg SSZ160361A - page 17

    17 PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a ...

  • Goodman Mfg SSZ160361A - page 18

    WIRING DIAGRAMS 18 WA RNI NG HIGH V OLTAGE! DISCONNECT AL L POWER BEFO RE SERVICING OR INST ALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERT Y DAMAGE, P ERSONAL INJURY O R DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. SSZ160[24-48]1A* COM ...

  • Goodman Mfg SSZ160361A - page 19

    WIRING DIAGRAMS 19 WA RNI NG HIGH V OLTAGE! DISCONNECT AL L POWER BEFO RE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERT Y DAMAGE, P ERSONAL INJURY O R DEATH. SSZ160[60]1AA U S E N.E. C . CL A SS 2 WIRE N O TE S : 1) T O IND OO R UNIT LO W V OL TAGE TER M INA L B LOC K & IND OO R T H ...

  • Goodman Mfg SSZ160361A - page 20

    WIRING DIAGRAMS 20 WA RNI NG HIGH V OLTAGE! DISCONNECT AL L POWER BEFO RE SERVICING OR INST ALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERT Y DAMAGE, P ERSONAL INJURY O R DEATH. SSZ160[60]1AB/AC Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. USE ...

Fabricant Goodman Mfg Catégorie Heat Pump

Les documents que nous recevons du fabricant de l'appareilGoodman Mfg SSZ160361A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Goodman Mfg
- manuels d’utilisations SSZ160361A
- fiches produit Goodman Mfg
- dépliants
- ou étiquettes-énergie Goodman Mfg SSZ160361A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Goodman Mfg SSZ160361A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Goodman Mfg SSZ160361A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Goodman Mfg SSZ160361A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Goodman Mfg SSZ160361A.

Manuel d’utilisation complet de l’appareil Goodman Mfg SSZ160361A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Goodman Mfg SSZ160361A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Goodman Mfg SSZ160361A.

Le manuel d’utilisation complet Goodman Mfg, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Goodman Mfg SSZ160361A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Goodman Mfg SSZ160361A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGoodman Mfg SSZ160361A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Goodman Mfg SSZ160361A - qui devraient nous aider dans les premières étapes lors de l'utilisation Goodman Mfg SSZ160361A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Goodman Mfg SSZ160361A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Goodman Mfg SSZ160361A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Goodman Mfg SSZ160361A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Goodman Mfg SSZ160361A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Goodman Mfg SSZ160361A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)